Recently, I saw some new friends when installing Mitsubishi plc programming software, the installation failed or can not be used after installation, etc. For this problem, this article briefly introduces the installation steps of Mitsubishi PLC programming software:

1. Software introduction:

1. Mitsubishi PLC programming software GXDeveloperversion8.86 Chinese version

Applicable to all series of Mitsubishi PLCs such as Q, QnU, QS, QnA, AnS, AnA, FX, etc. Support ladder diagram, instruction list, SFC, ST and FB, Label language programming, network parameter setting, program online Change, monitor and debug, with the function of reading and writing PLC program from different places, supporting simulation GX-Simulator6.

2. Mitsubishi PLC programming software

GX-Works2 Mitsubishi PLC programming software is suitable for Q series, L series, FX series PLC, is the latest programming software of Mitsubishi, the software comes with simulation function, compatible with GXDeveloper, is an upgraded version of GXDeveloper8.86! Applicable to all series of Mitsubishi PLC programming, can realize PLC data and hmi, motion controller data sharing.

2. Installation environment:

1. Mitsubishi PLC programming software GXDeveloperversion8.86 Chinese version is currently the most used, due to the earlier version, the software has not been updated so fast, currently does not support WIN7 system and above version system, special 64-bit WIN7 operating system, in this Unable to use in the system environment, it is recommended to use the XP operating system to install and use.

2.GX-Works2 Mitsubishi PLC programming software The most current Mitsubishi PLC programming software, many friends who use laptops, now laptops update faster, basically WIN7 operating system, you must use the latest Mitsubishi PLC programming Software WORKS2. But the notebook is still not convenient enough to use, such as downloading the program is more troublesome, can only be transmitted through the USB port, there is no COM port.

Three. Installation notes (for GXDeveloper8.86 version)

1. Install the general environment first, enter the SW8D5C-GPPW-C/EnvMEL folder, click "SETUP" to install;

Most of Mitsubishi's software must first install the "environment", otherwise you can not continue to install, this step is easy to handle, if you can not install, the system will prompt you to need the installation environment.

2. Enter the SW8D5C-GPPW-C folder and click “SETUP” to install. It is best to turn off the anti-virus software during installation.

3. Enter the general serial number of the GX series software (the serial number can be applied to the official website of Mitsubishi PLC).

4. Special attention: "Monitoring dedicated" can not be ticked, otherwise the software can only monitor, this place is also the place with the most problems. This is where many friends will easily pick the wrong place.

5. According to the prompt option, after running the Mitsubishi PLC programming software test program is normal, if the normal installation is successful, if the program is not normal, it may be because the operating system DLL file or other system files are lost, the general program will prompt Caused by the lack of files.

Plastic SCSI Cover Section

Small computer system interface (SCSI) is an independent processor standard for system level interfaces between computers and intelligent devices (hard disks, floppy drives, optical drives, printers, scanners, etc.). SCSI is an intelligent universal interface standard.

SCSI-3
In 1995, the more high-speed SCSI-3, called ultrasci, was born, and the data transmission rate reached 20MB / s. It increases the synchronous transmission clock frequency to 20MB / s and improves the data transmission rate. If 16 bit wide mode is used, the data transmission rate can be increased to 40MB / s. This version of SCSI uses a 68 pin interface, which is mainly used on hard disks. The typical characteristic of SCSI-3 is that the bus frequency is greatly increased and the signal interference is reduced to enhance its stability.

There are many models of SCSI-3. Ultra (FAST-20) has a transmission frequency of 20MHz, a data bandwidth of 8 bits and a transmission rate of 20MBps

Ultra wide has a transmission frequency of 20MHz, a data bandwidth of 16 bits and a transmission rate of 40mbps

The transmission frequency of ultra 2 is 80 MHz, the data bandwidth is 16 bits, and the transmission rate is 80 Mbps

The transmission frequency of ultra 160 is 80 MHz, the data bandwidth is 16 bits, and the transmission rate is 160 Mbps

The transmission frequency of ultra 320 is 80MHz, the data bandwidth is 16 bits, and the transmission rate is 320mbps

The transmission frequency of ultra 640 is 160MHz, the data bandwidth is 16 bits, and the transmission rate is 640mbps

Plastic SCSI Cover

ShenZhen Antenk Electronics Co,Ltd , https://www.antenkcon.com

This entry was posted in on